FIRE SPRINKLERS INSPECTIONS

ADDRESS: 13700 Foothill Blvd. #920866

Los Angeles CA. 91342

CALL US or SEND US A TEXT MESSAGE

LOS ANGELES AREA: (323) 347-1158

SAN FERNANDO VALLEY: (818) 489-8762

Error: Contact form not found.

What's more important than knowing your loved ones and your property are protected?

Fire Sprinkler systems provide a high level of life safety. The combination of automatic fire sprinkler systems and early warning detection systems reduces the chance of overall injuries, loss of life and property damages by at least 50%

RESIDENTIAL - COMMERCIAL - INDUSTRIAL

Design - Installation - Service - Repairs - Testing - 24/7 Monitoring Services

Serving Southern California with 30 Years of experience!

CALL or TEXT: 323-347-1158 / 818-489-8762

13700 Foothill Blvd. #920866, Los Angeles CA. 91342

info@suthernfire.com

Scroll down to see our Testimonials, licenses and certifications!

With 30 years of experience in the fire protection business and repeat clients across the state, we are helping protect lives and property in our community with honesty, work ethics and integrity.

When you choose Suthern Fire protection Inc. to install or service your fire protection systems, you are hiring a team of people who will complete your job with the highest level of integrity.

Fire Sprinkler Systems offer twenty-four-hour seven days a week protection in the event of an emergency. Contact us and a specialist will help you design, install, test or give service to your new or existing fire sprinkler system in Southern California.

Two identical rooms furnished the same, one equipped with a residential fire sprinkler system and one without, are set on fire to show the dramatic difference fire sprinklers make on preserving life and property.

With Suthern Fire Protection Inc. you obtain experienced and knowledgeable staff, all our fire protection systems are designed by certified and fully experienced technicians. We have a certified staff of Engineering Technicians utilizing Computer Aided Drafting (CAD) to develop fire protection shop drawing, hydraulic calculations, equipment submittals, operation and maintenance manuals for your projects. Shop drawings are developed in a timely manner to facilitate delivery of your fire protection system to meet your installation schedule. Suthern Fire Protection Inc. is experienced, qualified, certified, and highly trained to safely and professionally meet your installation needs.

residential - commercial - INDUSTRIAL

The National Fire Protection Association’s standards (NFPA 25) list specific requirement for what equipment needs to be inspected or tested and how often. Some items need to be inspected or tested weekly, monthly, quarterly, semiannually, annually and every five years. The following is an example of what should be checked during the quarterly and annually inspections for a typical wet or dry sprinkler system.

1.- Inspect valves to verify that they are in the following conditions

* In their normal open or closed position

* Properly sealed, locked, or supervised

*Accessible

* Free of physical damages

* Appropriately labeled

* (Alarm valves) Retarding chamber or alarm drains functioning and with no leaks.

  1. Inspect all of the gauges to verify they are in the following conditions:

For wet systems:

* Gauges shall be inspected monthly to ensure they are in good condition and that normal water supply pressure is being maintained.

For dry systems:

  • The gauge on the supply side of the dry pipe valve must indicate that the normal supply water pressure is being maintained.
  • * The gauge on the quick-opening device, if provided, must indicate the same pressure as the gauge on the system side of the dry pipe valve.
  • Gauges on systems with low air or nitrogen pressure alarms must be inspected monthly.
  1. Inspect water flow alarm and supervisory alarm devices for physical damage.
  2. Inspect and test the water flow alarm by opening the test connection on a wet pipe system and the bypass connection on a dry pipe system.
  3. If the sprinkler system is hydraulic calculated, inspect the hydraulic name plate to ensure that it’s attached and easily seen.
  4. Inspect fire department connections to make sure they are visible and undamaged, and ensure that gaskets and valves are not leaking or damaged.
  5. Inspect pressure reducing valves and relief valves, if any, to verify that they are:

* In the opening position

* Not leaking

* Maintaining downstream pressures in accordance with the design criteria.

* In good condition, with handles installed and unbroken

Annual Inspection

The annual inspection includes everything in the quarterly inspection as well as the following:

  1. Inspect all sprinkler heads, including the pipes and fittings (floor level only).
  2. Ensure that there are extra sprinkler heads on site, as well as tools to replace out sprinkler heads.
  3. Inspect interior of dry pipe valves while resetting (if applicable)
  4. Conduct a main drain water flow test to determine if there has been a change in the condition of the water supply. ( This test is required quarterly if the water is supplied through a backflow preventer and/or pressure reducing valve)

Contact us and a Suthern Fire Protection Inc. representative will answer all your questions.

These are just some of the requirements there are much more depending on the type of system on site. Whatever system you have, Suthern Fire Protection Inc. can handle your required inspection and testing needs, as well as full fire sprinkler, fire alarm, installation or repairs. Suthern Fire Protection Inc. can also resolve any issues found during the inspections, to help keep your system functioning when it is needed most - when lives are on the line during a fire.